over operating free-air temperature range (unless otherwise noted)(1)(2)(3) | MIN | MAX | UNIT |
---|
Supply voltage | VDD | –0.3 | 20 | V |
Output Voltage (DC) | VOUT | –0.3 | VDD +0.3 | V |
Output Voltage (100-ns Pulse) | VOUT | –2 | VDD +0.3 | V |
Input Voltage IN | –5 | VDD +0.3 | V |
Input Voltage EN | -0.3 | VDD +0.3 | |
Operating junction temperature, TJ | –40 | 150 | °C |
Lead temperature | Soldering, 10 s | | 300 | °C |
Reflow | | 260 |
Storage temperature, Tstg | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) All voltages are with respect to GND unless otherwise noted. Currents are positive into, negative out of the specified terminal. See
Section 6.4 of the data sheet for thermal limitations and considerations of packages.
(3) These devices are sensitive to electrostatic discharge; follow proper device handling procedures.