JAJSOG3 December   2023 UCC28750

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Timing Requirements
    8. 6.8 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Detailed Pin Descriptions
      1. 7.3.1 VDD - Input Bias
      2. 7.3.2 DRV - Gate Drive Out
      3. 7.3.3 CS - Current Sensing
      4. 7.3.4 FB - Feedback
      5. 7.3.5 FLT - Fault
      6. 7.3.6 GND - Ground Return
    4. 7.4 Feature Description
      1. 7.4.1 Soft Start
      2. 7.4.2 Control Law
      3. 7.4.3 Frequency Dithering
      4. 7.4.4 Fault Protections
        1. 7.4.4.1 VDD Overvoltage and Undervoltage Lockout
        2. 7.4.4.2 Internal Overtemperature Protection
        3. 7.4.4.3 Output Overpower Protection
        4. 7.4.4.4 Output Short-Circuit Protection
        5. 7.4.4.5 FLT Pin Protections
      5. 7.4.5 Slope Compensation
    5. 7.5 Device Functional Modes
      1. 7.5.1 Off
      2. 7.5.2 Startup
      3. 7.5.3 On
      4. 7.5.4 Fault
      5. 7.5.5 Disabled
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Application
      2. 8.2.2 Design Requirements
      3. 8.2.3 Detailed Design Procedure
        1. 8.2.3.1 Input Bulk Capacitance with Minimum Bulk Voltage
        2. 8.2.3.2 Transformer Turns Ratio and Inductance
        3. 8.2.3.3 Current Sense and Slope Compensation Network
        4. 8.2.3.4 Output Capacitors
        5. 8.2.3.5 VDD Capacitance, CVDD
      4. 8.2.4 Application Performance Plots
        1. 8.2.4.1 Startup
        2. 8.2.4.2 Load Transients
        3. 8.2.4.3 Q1 Drain Voltage Evaluation
      5. 8.2.5 What to Do and What Not to Do
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Soft Start

The UCC28750 includes a soft start feature to lower the peak current during the start-up phase. At the beginning of a normal startup operation the output voltage of the system is zero, and the capacitors at the output are discharged. In this scenario the FB pin is pulled up to the internal VREF value. In a controller without a soft start feature, the controller switches at the highest power mode. The soft-start feature limits the stresses on the system and switching devices by clamping the internal FB voltage during the start-up phase to a stepping ramp. Now, the output voltage can rise in a controlled manner.

The internal soft-start ramp is compared to the FB pin voltage, and as long as the internal ramp is lower than the FB pin voltage, the internal ramp is in control of the power delivery level. As the output voltage increases to the programmed level, the FB pin decreases and takes control instead of the internal soft start ramp. The full ramp time of soft start is fixed internally to 4.3ms, tss.

GUID-20230605-SS0I-B5BH-6JBX-KWPNLBQ8C6RJ-low.svg Figure 7-8 Softstart Ramp on Startup