JAJSQ97J
may 2009 – january 2021
XIO2001
PRODUCTION DATA
1
1
特長
2
アプリケーション
3
概要
4
Revision History
5
Pin Configuration and Functions
Pin Assignments
Pin Descriptions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
Handling Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information #GUID-4E9F689A-942D-492C-8F28-F3CC5F1BD0E6/SCPS2129637AN1
6.5
Nominal Power Consumption
6.6
PCI Express Differential Transmitter Output Ranges
6.7
PCI Express Differential Receiver Input Ranges
6.8
PCI Express Differential Reference Clock Input Ranges #GUID-60875016-888B-4DD4-A309-543B497BAC9F/SCPS1718455
6.9
PCI Bus Electrical Characteristics
6.10
3.3-V I/O Electrical Characteristics
6.11
PCI Bus Timing Requirements
6.12
Power-Up/-Down Sequencing
6.12.1
Power-Up Sequence
6.12.2
Power-Down Sequence
7
Parameter Measurement Information
25
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Bridge Reset Features
8.3.2
PCI Express Interface
8.3.2.1
2.5-Gb/s Transmit and Receive Links
8.3.2.2
Transmitter Reference Resistor
8.3.2.3
Reference Clock
8.3.2.4
Reset
8.3.2.5
Beacon
8.3.2.6
Wake
8.3.2.7
Initial Flow Control Credits
8.3.2.8
PCI Express Message Transactions
8.3.3
PCI Port Arbitration
8.3.3.1
Classic PCI Arbiter
8.3.4
Configuration Register Translation
8.3.5
PCI Interrupt Conversion to PCI Express Messages
8.3.6
PME Conversion to PCI Express Messages
8.3.7
PCI Express to PCI Bus Lock Conversion
8.3.8
Two-Wire Serial-Bus Interface
8.3.8.1
Serial-Bus Interface Implementation
8.3.8.2
Serial-Bus Interface Protocol
8.3.8.3
Serial-Bus EEPROM Application
8.3.8.4
Accessing Serial-Bus Devices Through Software
8.3.9
Advanced Error Reporting Registers
8.3.10
Data Error Forwarding Capability
8.3.11
General-Purpose I/O Interface
8.3.12
Set Slot Power Limit Functionality
8.3.13
PCI Express and PCI Bus Power Management
8.3.14
Auto Pre-Fetch Agent
8.4
Register Maps
8.4.1
Classic PCI Configuration Space
8.4.2
Vendor ID Register
8.4.3
Device ID Register
8.4.4
Command Register
8.4.5
Status Register
8.4.6
Class Code and Revision ID Register
8.4.7
Cache Line Size Register
8.4.8
Primary Latency Timer Register
8.4.9
Header Type Register
8.4.10
BIST Register
8.4.11
Device Control Base Address Register
8.4.12
Primary Bus Number Register
8.4.13
Secondary Bus Number Register
8.4.14
Subordinate Bus Number Register
8.4.15
Secondary Latency Timer Register
8.4.16
I/O Base Register
8.4.17
I/O Limit Register
8.4.18
Secondary Status Register
8.4.19
Memory Base Register
8.4.20
Memory Limit Register
8.4.21
Prefetchable Memory Base Register
8.4.22
Prefetchable Memory Limit Register
8.4.23
Prefetchable Base Upper 32-Bit Register
8.4.24
Prefetchable Limit Upper 32-Bit Register
8.4.25
I/O Base Upper 16-Bit Register
8.4.26
I/O Limit Upper 16-Bit Register
8.4.27
Capabilities Pointer Register
8.4.28
Interrupt Line Register
8.4.29
Interrupt Pin Register
8.4.30
Bridge Control Register
8.4.31
Capability ID Register
8.4.32
Next Item Pointer Register
8.4.33
Subsystem Vendor ID Register
8.4.34
Subsystem ID Register
8.4.35
Capability ID Register
8.4.36
Next Item Pointer Register
8.4.37
Power Management Capabilities Register
8.4.38
Power Management Control/Status Register
8.4.39
Power Management Bridge Support Extension Register
8.4.40
Power Management Data Register
8.4.41
MSI Capability ID Register
8.4.42
Next Item Pointer Register
8.4.43
MSI Message Control Register
8.4.44
MSI Message Lower Address Register
8.4.45
MSI Message Upper Address Register
8.4.46
MSI Message Data Register
8.4.47
PCI Express Capability ID Register
8.4.48
Next Item Pointer Register
8.4.49
PCI Express Capabilities Register
8.4.50
Device Capabilities Register
8.4.51
Device Control Register
8.4.52
Device Status Register
8.4.53
Link Capabilities Register
8.4.54
Link Control Register
8.4.55
Link Status Register
8.4.56
Serial-Bus Data Register
8.4.57
Serial-Bus Word Address Register
8.4.58
Serial-Bus Slave Address Register
8.4.59
Serial-Bus Control and Status Register
8.4.60
GPIO Control Register
8.4.61
GPIO Data Register
8.4.62
TL Control and Diagnostic Register 0
8.4.63
Control and Diagnostic Register 1
8.4.64
Control and Diagnostic Register 2
8.4.65
Subsystem Access Register
8.4.66
General Control Register
8.4.67
Clock Control Register
8.4.68
Clock Mask Register
8.4.69
Clock Run Status Register
8.4.70
Arbiter Control Register
8.4.71
Arbiter Request Mask Register
8.4.72
Arbiter Time-Out Status Register
8.4.73
Serial IRQ Mode Control Register
8.4.74
Serial IRQ Edge Control Register
8.4.75
Serial IRQ Status Register
8.4.76
Pre-Fetch Agent Request Limits Register
8.4.77
Cache Timer Transfer Limit Register
8.4.78
Cache Timer Lower Limit Register
8.4.79
Cache Timer Upper Limit Register
8.5
PCI Express Extended Configuration Space
8.5.1
Advanced Error Reporting Capability ID Register
8.5.2
Next Capability Offset/Capability Version Register
8.5.3
Uncorrectable Error Status Register
8.5.4
Uncorrectable Error Mask Register
8.5.5
Uncorrectable Error Severity Register
8.5.6
Correctable Error Status Register
8.5.7
Correctable Error Mask Register
8.5.8
Advanced Error Capabilities and Control Register
8.5.9
Header Log Register
8.5.10
Secondary Uncorrectable Error Status Register
8.5.11
Secondary Uncorrectable Error Severity
8.5.12
Secondary Error Capabilities and Control Register
8.5.13
Secondary Header Log Register
8.6
Memory-Mapped TI Proprietary Register Space
8.6.1
Device Control Map ID Register
8.6.2
Revision ID Register
8.6.3
GPIO Control Register
8.6.4
GPIO Data Register
8.6.5
Serial-Bus Data Register
8.6.6
Serial-Bus Word Address Register
8.6.7
Serial-Bus Slave Address Register
8.6.8
Serial-Bus Control and Status Register
8.6.9
Serial IRQ Mode Control Register
8.6.10
Serial IRQ Edge Control Register
8.6.11
Serial IRQ Status Register
8.6.12
Pre-Fetch Agent Request Limits Register
8.6.13
Cache Timer Transfer Limit Register
8.6.14
Cache Timer Lower Limit Register
8.6.15
Cache Timer Upper Limit Register
9
Application, Implementation, and Layout
9.1
Application Information
9.2
Typical Application
9.2.1
In-Card Implementation
9.2.1.1
Design Requirements
9.2.1.1.1
VCCP Clamping Rail
9.2.1.1.2
Combined Power Outputs
9.2.1.1.3
Auxiliary Power
9.2.1.1.4
VSS and VSSA Pins
9.2.1.1.5
Capacitor Selection Recommendations
9.2.1.2
Detailed Design Procedure
9.2.1.2.1
PCI Bus Interface
9.2.1.2.1.1
Bus Parking
9.2.1.2.1.2
I/O Characteristics
9.2.1.2.1.3
Clamping Voltage
9.2.1.2.1.4
PCI Bus Clock Run
9.2.1.2.1.5
PCI Bus External Arbiter
9.2.1.2.1.6
MSI Messages Generated from the Serial IRQ Interface
9.2.1.2.1.7
PCI Bus Clocks
9.2.2
External EEPROM
9.2.2.1
Design Requirements
9.2.2.2
Detailed Design Procedure
9.2.3
JTAG Interface
9.2.3.1
Design Requirements
9.2.3.2
Detailed Design Procedure
9.2.4
Combined Power
9.2.4.1
Design Requirements
9.2.4.2
Detailed Design Procedure
9.2.5
Power Filtering
9.2.5.1
Design Requirements
9.2.5.2
Detailed Design Procedure
9.3
Layout
9.3.1
Layout Guidelines
9.3.2
Layout Example
9.4
Power Supply Recommendations
9.4.1
1.5-V and 3.3-V Digital Supplies
9.4.2
1.5-V and 3.3-V Analog Supplies
9.4.3
1.5-V PLL Supply
9.4.4
Power-Up/Down Sequencing
9.4.5
Power Supply Filtering Recommendations
10
Device and Documentation Support
10.1
Documents Conventions
10.1.1
XIO2001 Definition
10.2
Documentation Support
10.2.1
Related Documents
10.2.1.1
ドキュメントの更新通知を受け取る方法
10.3
サポート・リソース
10.4
Trademarks
10.5
静電気放電に関する注意事項
10.6
用語集
11
Mechanical, Packaging, and Orderable Information
パッケージ・オプション
メカニカル・データ(パッケージ|ピン)
PNP|128
MPQF060E
ZWS|169
MPBGAK4B
ZAJ|144
MPBG878A
サーマルパッド・メカニカル・データ
PNP|128
PPTD154D
発注情報
jajsq97j_oa
jajsq97j_pm
6.2
Handling Ratings
MIN
MAX
UNIT
T
stg
Storage temperature range
–65
150
°C
V
ESD-HBM
(1)
Human body model ESD rating (R = 1.5 K, C = 100 pF)
2
kV
V
ESD-CDM
(1)
Charged device model ESD rating (200 pF)
500
V
(1)