DLPU114A August 2024 – November 2024 DLPC8445
Set Calibration Data | |
---|---|
Write Parameter(s) | |
Byte | Description |
Byte 0 |
Calibration Data Block 0 = SSI Data 1 = WPC Calib Data 2 = WPC Calib Matrix Data 3 = XPR Data 4 = XPR Waveform Data 5 = Surface Correction Data |
Bytes 1-2 |
Number of bytes to be written |
Bytes 3-4 |
Offset From Start Of Calib Block |
Bytes 5- Number of bytes passed |
Data |