Transformer turns ratio (a1):
The voltage drop across the RDS(on) of the primary side FETs is negligible. We assume a 0.5-V forward voltage drop in the output rectifiers.
Select transformer turns based on 70% duty cycle (DMAX) at minimum specified input voltage. This will give some room for dropout if a PFC front end is used.
Turns ratio rounded to the nearest whole turn.
Calculated typical duty cycle (DTYP) based on average input voltage.
Output inductor peak-to-peak ripple current is set to 20% of the output current.
Care must be taken in selecting the correct amount of magnetizing inductance (LMAG). The following equations calculate the minimum magnetizing inductance of the primary of the transformer (T1) to ensure the converter operates in current-mode control. As LMAG reduces, the increasing magnetizing current becomes an increasing proportion of the signal at the CS pin. If the magnetizing current increases enough it can swamp out the current sense signal across RCS and the converter will operate increasingly as if it were in voltage mode control rather than current mode.
Figure 19 shows the transformer primary and secondary currents during normal operation.
Calculate T1 secondary RMS current (ISRMS):
Secondary RMS current (ISRMS1) when energy is being delivered to the secondary: (OUTA = OUTD = HI or OUTB = OUTC = HI).
Secondary RMS current (ISRMS2) during freewheeling period: (OUTA = OUTC = HI or OUTB = OUTD = HI).
Secondary RMS current (ISRMS3) caused by the negative current in the opposing winding during freewheeling period, please refer to Figure 19.
Total secondary RMS current (ISRMS):
Calculate T1 Primary RMS Current (IPRMS):
T1 Primary RMS (IPRMS1) current when energy is being delivered to the secondary.
T1 Primary RMS (IPRMS2) current when the converter is free wheeling.
Total T1 primary RMS current (IPRMS):
We select a transformer with the following specifications:
Transformer Primary DC resistance:
Transformer Secondary DC resistance:
Estimated transformer core losses (PT1) are twice the copper loss.
NOTE
This is just an estimate and the total losses may vary based on magnetic design.
Calculate remaining power budget: