JAJSCF6G July   2016  – December  2019 TPS2660

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
    1.     概略回路図
  3. 概要
    1.     -60V電源における入力逆極性保護
  4. 改訂履歴
  5. 概要(続き)
  6. Device Comparison Table
  7. Pin Configuration and Functions
    1.     Pin Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Parameter Measurement Information
  10. 10Detailed Description
    1. 10.1 Overview
    2. 10.2 Functional Block Diagram
    3. 10.3 Feature Description
      1. 10.3.1 Undervoltage Lockout (UVLO)
      2. 10.3.2 Overvoltage Protection (OVP)
      3. 10.3.3 Reverse Input Supply Protection
      4. 10.3.4 Hot Plug-In and In-Rush Current Control
      5. 10.3.5 Overload and Short Circuit Protection
        1. 10.3.5.1 Overload Protection
          1. 10.3.5.1.1 Active Current Limiting
          2. 10.3.5.1.2 Electronic Circuit Breaker with Overload Timeout, MODE = OPEN
        2. 10.3.5.2 Short Circuit Protection
          1. 10.3.5.2.1 Start-Up With Short-Circuit On Output
        3. 10.3.5.3 FAULT Response
          1. 10.3.5.3.1 Look Ahead Overload Current Fault Indicator
        4. 10.3.5.4 Current Monitoring
        5. 10.3.5.5 IN, OUT, RTN, and GND Pins
        6. 10.3.5.6 Thermal Shutdown
        7. 10.3.5.7 Low Current Shutdown Control (SHDN)
    4. 10.4 Device Functional Modes
  11. 11Application and Implementation
    1. 11.1 Application Information
    2. 11.2 Typical Application
      1. 11.2.1 Design Requirements
      2. 11.2.2 Detailed Design Procedure
        1. 11.2.2.1 Step by Step Design Procedure
        2. 11.2.2.2 Programming the Current-Limit Threshold—R(ILIM) Selection
        3. 11.2.2.3 Undervoltage Lockout and Overvoltage Set Point
        4. 11.2.2.4 Programming Current Monitoring Resistor—RIMON
        5. 11.2.2.5 Setting Output Voltage Ramp Time—(tdVdT)
          1. 11.2.2.5.1 Case 1: Start-Up Without Load—Only Output Capacitance C(OUT) Draws Current During Start-Up
          2. 11.2.2.5.2 Case 2: Start-Up With Load—Output Capacitance C(OUT) and Load Draws Current During Start-Up
          3. 11.2.2.5.3 Support Component Selections—RFLTb and C(IN)
      3. 11.2.3 Application Curves
    3. 11.3 System Examples
      1. 11.3.1 Acive ORing Operation
      2. 11.3.2 Field Supply Protection in PLC, DCS I/O Modules
      3. 11.3.3 Simple 24-V Power Supply Path Protection
    4. 11.4 Do's and Don'ts
  12. 12Power Supply Recommendations
    1. 12.1 Transient Protection
  13. 13Layout
    1. 13.1 Layout Guidelines
    2. 13.2 Layout Example
  14. 14デバイスおよびドキュメントのサポート
    1. 14.1 デバイス・サポート
    2. 14.2 ドキュメントのサポート
      1. 14.2.1 関連資料
    3. 14.3 ドキュメントの更新通知を受け取る方法
    4. 14.4 コミュニティ・リソース
    5. 14.5 商標
    6. 14.6 静電気放電に関する注意事項
    7. 14.7 Glossary
  15. 15メカニカル、パッケージ、および注文情報

Electrical Characteristics

–40°C ≤ TA = TJ ≤ +125°C, V(IN) = 24 V, V(SHDN) = 2 V, R(ILIM) = 120 kΩ, IMON = FLT = OPEN, C(OUT) = 1 μF, C(dVdT) = OPEN. (All voltages referenced to GND, (unless otherwise noted))
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
SUPPLY VOLTAGE
V(IN) Operating input voltage 4.2 60 V
V(PORR) Internal POR threshold, rising 3.9 4 4.1 V
V(PORHys) Internal POR hysteresis 250 275 300 mV
IQ(ON) Supply current Enabled: V(SHDN) = 2 V 190 300 390 µA
IQ(OFF) V(SHDN) = 0 V 11 20 33 µA
I(VINR) Reverse input supply current V(IN) = –60 V, V(OUT) = 0 V 66 µA
V(OVC) Overvoltage clamp V(IN) > 42 V, TPS26602 only 36 37.5 40 V
UNDERVOLTAGE LOCKOUT (UVLO) INPUT
V(IN_UVLO) Factory set V(IN) undervoltage trip level V(IN) rising, V(UVLO) = 0 V 14.25 14.9 15.75 V
V(IN) falling, V(UVLO) = 0 V 13.25 13.8 14.75
V(SEL_UVLO) Internal UVLO select threshold 180 200 240 mV
V(UVLOR) UVLO threshold voltage, rising 1.175 1.19 1.225 V
V(UVLOF) UVLO threshold voltage, falling 1.08 1.1 1.125 V
I(UVLO) UVLO input leakage current 0 V ≤ V(UVLO) ≤ 60 V –100 0 100
nA
LOW IQ SHUTDOWN (SHDN) INPUT
V(SHDN) Output voltage I(SHDN) = 0.1 µA 2 2.7 3.4 V
V(SHUTF) SHDN threshold voltage for low IQ shutdown, falling 0.55 0.76 0.94 V
I(SHDN) Leakage current V(SHDN) = 0.4 V –10 µA
OVERVOLTAGE PROTECTION (OVP) INPUT
V(IN_OVP) Factory set V(IN) overvoltage trip level V(IN) rising, V(OVP) = 0 V 31 32.6 34 V
V(IN) falling, V(OVP) = 0 V 28.5 30.3 31.5
V(SEL_OVP) Internal OVP select threshold 180 200 240 mV
V(OVPR) Overvoltage threshold voltage, rising 1.17 1.19 1.225 V
V(OVPF) Overvoltage threshold, falling 1.085 1.1 1.125 V
I(OVP) OVP input leakage current 0 V ≤ V(OVP) ≤ 4 V –100 0 100 nA
OVPMAX Maximum external OVP setting TPS26600, TPS26601 only 55 V
OUTPUT RAMP CONTROL (dVdT)
I(dVdT) dVdT charging current V(dVdT) = 0 V 4 4.7 5.5 µA
R(dVdT) dVdT discharging resistance V(SHDN) = 0 V, with I(dVdT) = 10 mA sinking 14 Ω
GAIN(dVdT) dVdT to OUT gain V(OUT)/V(dVdT) 23.75 24.6 25.5 V/V
CURRENT LIMIT PROGRAMMING (ILIM)
V(ILIM) ILIM bias voltage 1 V
I(OL) Overload current limit R(ILIM) = 120 kΩ, V(IN) – V(OUT) = 1 V 0.085 0.1 0.115 A
R(ILIM) = 12 kΩ, V(IN) – V(OUT) = 1 V 0.95 1 1.05
R(ILIM) = 8 kΩ, V(IN) – V(OUT) = 1 V 1.425 1.5 1.575
R(ILIM) = 5.36 kΩ, V(IN) – V(OUT) = 1 V 2.11 2.23 2.35
I(OL_R-OPEN) R(ILIM) = OPEN, open resistor current limit (single point failure test: UL60950) 0.055
I(OL_R-SHORT) R(ILIM) = SHORT, shorted resistor current limit (single point failure test: UL60950) 0.095
I(CB) Circuit breaker detection threshold R(ILIM) = 120 kΩ, MODE = open 0.045 0.073 0.11 A
R(ILIM) = 5.36 kΩ, MODE = open 2 2.21 2.4
I(SCL) Short-circuit current limit R(ILIM) = 120 kΩ, V(IN) – V(OUT) = 5 V 0.08 0.1 0.12 A
R(ILIM) = 8 kΩ, V(IN) – V(OUT) = 5 V 1.425 1.5 1.575
R(ILIM) = 5.36 kΩ, V(IN) – V(OUT) = 5 V 2.11 2.23 2.35
I(FASTRIP) Fast-trip comparator threshold 1.87 × I(OL) + 0.015 A
CURRENT MONITOR OUTPUT (IMON)
GAIN(IMON) Gain factor I(IMON):I(OUT) 0.1 A ≤ I(OUT) ≤ 2 A 72 78.28 85 µA/A
PASS FET OUTPUT (OUT)
RON IN to OUT total ON resistance 0.1 A ≤ I(OUT) ≤ 2 A, TJ = 25°C 140 150 160
0.1 A ≤ I(OUT) ≤ 2 A, TJ = 85°C 210
0.1 A ≤ I(OUT) ≤ 2 A, –40°C ≤ TJ ≤ +125°C 80 150 250
Ilkg(OUT) OUT leakage current in Off state V(IN) = 60 V, V(SHDN)= 0 V, V(OUT) = 0 V, sourcing 12 µA
V(IN) = 0 V, V(SHDN)= 0 V, V(OUT) = 24 V, sinking 11
V(IN) = –60 V, V(SHDN)= 0 V, V(OUT) = 0 V, sinking 50
V(REVTH) V(IN) – V(OUT) threshold for reverse protection comparator, falling –15 –10 –5 mV
V(FWDTH) V(IN) – V(OUT) threshold for reverse protection comparator, rising 85 96 110 mV
FAULT FLAG (FLT): ACTIVE LOW
R(FLT) FLT pull-down resistance V(OVP) = 2 V, I(FLT) = 5 mA sinking 40 85 160 Ω
I(FLT) FLT input leakage current 0 V ≤ V(FLT) ≤ 60 V –200 200 nA
THERMAL SHUT DOWN (TSD)
T(TSD) TSD threshold, rising 157 ºC
T(TSDhyst) TSD hysteresis 10 ºC
MODE
MODE_SEL Thermal fault mode selection MODE = 402 kΩ to RTN Current limiting with latch
MODE = Open Circuit breaker mode with auto-retry
MODE = Open (TPS26601 only) Circuit breaker mode with latch
MODE = Short to RTN Current limiting with auto-retry