JAJSF70C July   2015  – July 2024 TUSB4020BI-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 3.3V I/O Electrical Characteristics
    6. 5.6 Hub Input Supply Current
    7. 5.7 Power-Up Timing Requirements
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Battery Charging Features
      2. 6.3.2 USB Power Management
      3. 6.3.3 Clock Generation
      4. 6.3.4 Power-Up and Reset
    4. 6.4 Device Functional Modes
      1. 6.4.1 External Configuration Interface
    5. 6.5 Programming
      1. 6.5.1 One-Time Programmable (OTP) Configuration
      2. 6.5.2 I2C EEPROM Operation
      3. 6.5.3 SMBus Target Operation
    6. 6.6 Register Maps
      1. 6.6.1 Configuration Registers
        1. 6.6.1.1  ROM Signature Register (offset = 0h) [reset = 0h]
        2. 6.6.1.2  Vendor ID LSB Register (offset = 1h) [reset = 51h]
        3. 6.6.1.3  Vendor ID MSB Register (offset = 2h) [reset = 4h]
        4. 6.6.1.4  Product ID LSB Register (offset = 3h) [reset = 25h]
        5. 6.6.1.5  Product ID MSB Register (offset = 4h) [reset = 80h]
        6. 6.6.1.6  Device Configuration Register (offset = 5h) [reset = 1Xh]
        7. 6.6.1.7  Battery Charging Support Register (offset = 6h) [reset = 0Xh]
        8. 6.6.1.8  Device Removable Configuration Register (offset = 7h) [reset = 0Xh]
        9. 6.6.1.9  Port Used Configuration Register (offset = 8h) [reset = 0h]
        10. 6.6.1.10 PHY Custom Configuration Register (offset = 9h) [reset = 0h]
        11. 6.6.1.11 Device Configuration Register 2 (offset = Ah)
        12. 6.6.1.12 UUID Registers (offset = 10h to 1Fh)
        13. 6.6.1.13 Language ID LSB Register (offset = 20h)
        14. 6.6.1.14 Language ID MSB Register (offset = 21h)
        15. 6.6.1.15 Serial Number String Length Register (offset = 22h)
        16. 6.6.1.16 Manufacturer String Length Register (offset = 23h)
        17. 6.6.1.17 Product String Length Register (offset = 24h)
        18. 6.6.1.18 Serial Number Registers (offset = 30h to 4Fh)
        19. 6.6.1.19 Manufacturer String Registers (offset = 50h to 8Fh)
        20. 6.6.1.20 Product String Registers (offset = 90h to CFh)
        21. 6.6.1.21 Additional Feature Configuration Register (offset = F0h)
        22. 6.6.1.22 Charging Port Control Register (offset = F2h)
        23. 6.6.1.23 Device Status and Command Register (offset = F8h)
  8. Application and Implementation
    1. 7.1 Application Information
      1. 7.1.1 Crystal Requirements
      2. 7.1.2 Input Clock Requirements
    2. 7.2 Typical Applications
      1. 7.2.1 Upstream Port Implementation
        1. 7.2.1.1 Design Requirements
        2. 7.2.1.2 Detailed Design Procedure
        3. 7.2.1.3 Application Curves
      2. 7.2.2 Downstream Port 1 Implementation
      3. 7.2.3 Downstream Port 2 Implementation
      4. 7.2.4 VBUS Power Switch Implementation
      5. 7.2.5 Clock, Reset, and Miscellaneous
      6. 7.2.6 Power Implementation
  9. Power Supply Recommendations
    1. 8.1 Power Supply
    2. 8.2 Downstream Port Power
    3. 8.3 Ground
  10. Layout
    1. 9.1 Layout Guidelines
      1. 9.1.1 Placement
      2. 9.1.2 Package Specific
      3. 9.1.3 Differential Pairs
    2. 9.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 ドキュメントの更新通知を受け取る方法
    3. 10.3 サポート・リソース
    4. 10.4 Trademarks
    5. 10.5 静電気放電に関する注意事項
    6. 10.6 用語集
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

I2C EEPROM Operation

The TUSB4020BI-Q1 supports a single-controller, standard mode (100kbps) connection to a dedicated I2C EEPROM when the I2C interface mode is enabled. In I2C mode, the TUSB4020BI-Q1 reads the contents of the EEPROM at bus address 1010000b using 7-bit addressing starting at address 0.

If the value of the EEPROM contents at byte 00h equals 55h, the TUSB4020BI-Q1 loads the configuration registers according to the EEPROM map. If the first byte is not 55h, the TUSB4020BI-Q1 exits the I2C mode and continues execution with the default values in the configuration registers. The hub does not connect on the upstream port until the configuration is completed. If the TUSB4020BI-Q1 detects an unprogrammed EEPROM (value other than 55h), the device enters programming mode and a programming endpoint within the hub is enabled.

Note, the bytes located above offset Ah are optional. The requirement for data in those addresses depends on the options configured in the Device Configuration, Phy Custom Configuration, and Device Configuration 2 registers.

For details on I2C operation, refer to the UM10204 I2C-bus Specification and User Manual.