JAJSFQ3A July 2018 – September 2019 TPS56637
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
ON-TIME TIMER CONTROL | ||||||
tON(MIN) | Minimum on time(1) | 50 | ns | |||
tOFF(MIN) | Minimum off time | VFB = 0.5 V, measure SW at 50% VIN, Eco-mode | 200 | 300 | ns | |
SOFT START | ||||||
TSS | Soft start time | Internal soft-start time | 2 | ms | ||
OUTPUT UNDERVOLTAGE PROTECTION | ||||||
TUVP_WAIT | UV protection hiccup wait time | UV triggered (VFB lower than 65% VFB_nom) | 0.25 | ms | ||
TUVP_HICCUP | UV protection hiccup time before recovery | 25 | ms |