JAJSFR6A July 2018 – November 2018 ADS1219
PRODUCTION DATA.
The ADS1219 offers a I2C timeout feature that can be used to recover communication when a serial interface transmission is interrupted. If the host initiates contact with the ADS1219 but subsequently remains idle for 14000 · tMOD before completing a command, the ADS1219 interface is reset. If the ADS1219 interface resets because of a timeout condition, the host must abort the transaction and restart the communication again by issuing a new START condition.