JAJSLK0B march   2021  – june 2023 TMUX7462F

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Thermal Information
    4. 6.4  Recommended Operating Conditions
    5. 6.5  Electrical Characteristics (Global)
    6. 6.6  ±15 V Dual Supply: Electrical Characteristics
    7. 6.7  ±20 V Dual Supply: Electrical Characteristics
    8. 6.8  12 V Single Supply: Electrical Characteristics
    9. 6.9  36 V Single Supply: Electrical Characteristics
    10. 6.10 Typical Characteristics
  8. Parameter Measurement Information
    1. 7.1  On-Resistance
    2. 7.2  On-Leakage Current
    3. 7.3  Input and Output Leakage Current under Overvoltage Fault
    4. 7.4  Fault Response Time
    5. 7.5  Fault Recovery Time
    6. 7.6  Fault Flag Response Time
    7. 7.7  Fault Flag Recovery Time
    8. 7.8  Fault Drain Enable Time
    9. 7.9  Inter-Channel Crosstalk
    10. 7.10 Bandwidth
    11. 7.11 THD + Noise
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Flat ON-Resistance
      2. 8.3.2 Protection Features
        1. 8.3.2.1 Input Voltage Tolerance
        2. 8.3.2.2 Powered-Off Protection
        3. 8.3.2.3 Fail-Safe Logic
        4. 8.3.2.4 Overvoltage Protection and Detection
        5. 8.3.2.5 Latch-Up Immunity
        6. 8.3.2.6 EMC Protection
      3. 8.3.3 Overvoltage Fault Flags
      4. 8.3.4 Bidirectional Operation
    4. 8.4 Device Functional Modes
      1. 8.4.1 Normal Mode
      2. 8.4.2 Fault Mode
      3. 8.4.3 Truth Table
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 ドキュメントの更新通知を受け取る方法
    3. 10.3 サポート・リソース
    4. 10.4 Trademarks
    5. 10.5 静電気放電に関する注意事項
    6. 10.6 用語集
  12. 11Mechanical, Packaging, and Orderable Information

±15 V Dual Supply: Electrical Characteristics

VDD = +15 V ± 10%, VSS = –15 V ±10%, GND = 0 V (unless otherwise noted) 
Typical at VDD = +15 V, VSS = –15 V, TA = 25℃  (unless otherwise noted)
PARAMETER TEST CONDITIONS TA MIN TYP MAX UNIT
ANALOG SWITCH
RON On-resistance VS = –10 V to +10 V
ID = –10 mA
25°C 8.3 10.7
–40°C to +85°C 13.5
–40°C to +125°C 16
ΔRON On-resistance mismatch between channels VS = –10 V to +10 V
ID = –10 mA
25°C 0.05 0.45
–40°C to +85°C 0.5
–40°C to +125°C 0.6
RFLAT On-resistance flatness VS = –10 V to +10 V
ID = –10 mA
25°C 0.005 0.4
–40°C to +85°C 0.4
–40°C to +125°C 0.4
RON_DRIFT On-resistance drift VS = 0 V, IS = –10 mA –40°C to +125°C 0.04 Ω/°C
IS(ON)
ID(ON)
Channel on leakage current (1) Switch state is on,
VDD = 16.5 V, VSS = –16.5 V,
VS = VD = ±10 V
25°C –0.7 0.1 0.7 nA
–40°C to +85°C –2 2
–40°C to +125°C –15 15
FAULT CONDITION
IS(FA) Input leakage current
during overvoltage
VS = ± 60 V, GND = 0 V, 
VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V
–40°C to +125°C ±110 µA
IS(FA) Grounded Input leakage current
during overvoltage with
grounded supply voltages
VS = ± 60 V, GND = 0 V,
VDD = VSS = VFP = VFN= 0 V
–40°C to +125°C ±135 µA
IS(FA) Floating Input leakage current
during overvoltage with
floating supply voltages
VS = ± 60 V, GND = 0 V,
VDD = VSS = VFP = VFN= floating,
–40°C to +125°C ±140 µA
ID(FA) Output leakage current
during overvoltage
VS = ± 60 V, GND = 0 V, 
VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 5 V or floating
25°C –20 ±0.1 20 nA
–40°C to +85°C –30 30
–40°C to +125°C –60 60
ID(FA) Grounded Output leakage current
during overvoltage with
grounded supply voltages
VS = ± 60 V, GND = 0 V,
VDD = VSS = VFP = VFN = 0 V
25°C –30 ±0.01 30 nA
–40°C to +85°C –50 50
–40°C to +125°C –90 90
ID(FA) Floating Output leakage current
during overvoltage with
floating supply voltages
VS = ± 60 V, GND = 0 V,
VDD = VSS = VFP = VFN = floating
25°C ±0.6 µA
–40°C to +85°C ±1.2
–40°C to +125°C ±2.2
SWITCHING CHARACTERISTICS
tRESPONSE Fault response time VFP = 10 V, VFN = –10 V,
RL = 300 Ω, CL= 12 pF
25°C 100 350 ns
–40°C to +85°C 380
–40°C to +125°C 400
tRECOVERY Fault recovery time VFP = 10 V, VFN = –10 V,
RL = 300 Ω, CL= 12 pF
25°C 1600 4500 ns
–40°C to +85°C 4800
–40°C to +125°C 4800
tRESPONSE(FLAG) Fault flag response time VFP = 10 V, VFN = –10 V, 
VPU = 5 V, RPU = 1 kΩ, CL= 12 pF
25°C 250 ns
tRECOVERY(FLAG) Fault flag recovery time VFP = 10 V, VFN = –10 V, 
VPU = 5 V, RPU = 1 kΩ, CL= 15 pF
25°C 1.2 µs
tRESPONSE(DR) Fault output response time VFP = 10 V, VFN = –10 V, 
VPU = 5 V, CL= 12 pF
25°C 2.7 µs
XTALK Intra-channel crosstalk RS = 50 Ω, RL = 50 Ω, CL = 5 pF,
VS = 200 mVRMS, VBIAS = 0 V, f = 1 MHz
25°C –100 dB
BW –3 dB bandwidth (WQFN Package) RS = 50 Ω, RL = 50 Ω, CL = 5 pF,
VS = 200 mVRMS, VBIAS = 0 V
25°C 650 MHz
BW –3 dB bandwidth (TSSOP Package) RS = 50 Ω, RL = 50 Ω, CL = 5 pF,
VS = 200 mVRMS, VBIAS = 0 V
25°C 580 MHz
ILOSS Insertion loss RS = 50 Ω, RL = 50 Ω, CL = 5 pF,
VS = 200 mVRMS, VBIAS = 0 V, f = 1 MHz
25°C –0.7 dB
THD+N Total harmonic distortion plus noise RS = 50 Ω, RL = 10 kΩ,
VS = 15 VPP, VBIAS = 0 V,
f = 20 Hz to 20 kHz
25°C 0.0006 %
CS(ON),
CD(ON)
Input/Output on-capacitance f = 1 MHz, VS = 0 V 25°C 14 pF
POWER SUPPLY
IDD VDD supply current VDD = VFP = 16.5 V,
VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.32 0.5 mA
–40°C to +85°C 0.5
–40°C to +125°C 0.6
ISS VSS supply current VDD = VFP = 16.5 V,
VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.26 0.4 mA
–40°C to +85°C 0.4
–40°C to +125°C 0.5
IGND GND current VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.06 mA
IFP VFP supply current VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 10 µA
IFN VFN supply current VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 10 µA
IDD(FA) VDD supply current under fault VS = ± 60 V,
VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.27 0.5 mA
–40°C to +85°C 0.5
–40°C to +125°C 0.6
ISS(FA) VSS supply current under fault VS = ± 60 V,
VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.2 0.3 mA
–40°C to +85°C 0.3
–40°C to +125°C 0.4
IGND(FA) GND current under fault VS = ± 60 V,
VDD = VFP = 16.5 V, VSS = VFN =  –16.5 V,
VDR = 0 V, 5 V, or VDD
25°C 0.15 mA
IFP(FA) VFP supply current under fault 25°C 10 µA
IFN(FA) VFN supply current under fault 25°C 10 µA
When VS is at a voltage potential, VD is floating, or when VD is at a voltage potential, VS is floating.