JAJSRW4
October 2024
AMC0386-Q1
ADVANCE INFORMATION
1
1
特長
2
アプリケーション
3
概要
Device Comparison Table
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Power Ratings
5.6
Insulation Specifications
5.7
Safety-Related Certifications
5.8
Safety Limiting Values
5.9
Electrical Characteristics
5.10
Switching Characteristics
5.11
Timing Diagrams
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
Analog Input
6.3.2
Modulator
6.3.3
Isolation Channel Signal Transmission
6.3.4
Digital Output
6.3.4.1
Output Behavior in Case of a Fullscale Input
6.3.4.2
Output Behavior in Case of a Missing High-Side Supply
6.4
Device Functional Modes
7
Application and Implementation
7.1
Best Design Practices
7.2
Power Supply Recommendations
7.3
Layout
7.3.1
Layout Guidelines
7.3.2
Layout Example
8
Device and Documentation Support
8.1
Documentation Support
8.1.1
Related Documentation
8.2
ドキュメントの更新通知を受け取る方法
8.3
サポート・リソース
8.4
Trademarks
8.5
静電気放電に関する注意事項
8.6
用語集
9
Revision History
10
Mechanical, Packaging, and Orderable Information
10.1
Mechanical Data
1
特長
車載アプリケーション用に AEC-Q100 認定済み:
温度グレード 1:-40℃~125℃、T
A
外付け抵抗なしで AC または DC 電圧を直接検出できる内蔵高電圧抵抗分圧器
システムレベルのキャリブレーションなしで、温度範囲と寿命全体にわたって 1% 未満の高精度
電源電圧範囲:
ハイサイド (AVDD):3.0V~5.5V
ローサイド (DVDD):2.7V~5.5V
小さい DC 誤差:
オフセット誤差:
±0.9mV (最大値)
オフセット ドリフト:
±7µV/°C (最大値)
減衰誤差:
±0.25% (最大値)
減衰ドリフト:
±40ppm/°C (最大値)
「高 CMTI:100V/ns (最小値)
ハイサイド電源喪失の検出
低 EMI:CISPR-11 および CISPR-25 規制に準拠
利用可能な入力オプション:
AMC0386M
04
-Q1
:400V、8MΩ
AMC0386M
06
-Q1
: 600V、10MΩ
AMC0386M
10
-Q1
: 1000V、12.5MΩ
低 EMI:CISPR-11 および CISPR-25 規格に準拠
安全関連認証:
DIN EN IEC 60747-17 (VDE 0884-17) に準拠した強化絶縁耐圧:7000V
PK
UL 1577 に準拠した絶縁耐圧:5000V
RMS
(1 分間)