23 |
DIAG14_OPEN |
RC |
0h |
LED-Open fault flag for DRAIN15 and DIAG14, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
22 |
DIAG14_SHORT |
RC |
0h |
LED-short fault flag for DIAG15 and DIAG14, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
21 |
DIAG12_OPEN |
RC |
0h |
LED-open fault flag for DRAIN13 and DIAG12, read to clear the fault
HIGH = LED open fault detected
LOW = LED-open fault not detected |
20 |
DIAG12_SHORT |
RC |
0h |
LED-short fault flag for DIAG13 and DIAG12, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
19 |
DIAG10_OPEN |
RC |
0h |
LED-open fault flag for DRAIN11 and DIAG10, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
18 |
DIAG10_SHORT |
RC |
0h |
LED-short fault flag for DIAG11 and DIAG10, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
17 |
DIAG8_OPEN |
RC |
0h |
LED-open fault flag for DRAIN9 and DIAG8, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
16 |
DIAG8_SHORT |
RC |
0h |
LED-short fault flag for DIAG9 and DIAG8, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
15 |
DIAG6_OPEN |
RC |
0h |
LED-open fault flag for DRAIN7 and DIAG6, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
14 |
DIAG6_SHORT |
RC |
0h |
LED-short fault flag for DIAG7 and DIAG6, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
13 |
DIAG4_OPEN |
RC |
0h |
LED-open fault flag for DRAIN5 and DIAG4, read to clear the fault
HIGH = LED open fault detected
LOW = LED-open fault not detected |
12 |
DIAG4_SHORT |
RC |
0h |
LED-short fault flag for DIAG5 and DIAG4, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
11 |
DIAG2_OPEN |
RC |
0h |
LED-open fault flag for DRAIN3 and DIAG2, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
10 |
DIAG2_SHORT |
RC |
0h |
LED-short fault flag for DIAG3 and DIAG2, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
9 |
DIAG0_OPEN |
RC |
0h |
LED-open fault flag for DRAIN1 and DIAG0, read to clear the fault
HIGH = LED-open fault detected
LOW = LED-open fault not detected |
8 |
DIAG0_SHORT |
RC |
0h |
LED-short fault flag for DIAG1 and DIAG0, read to clear the fault
HIGH = LED-short fault detected
LOW = LED-short fault not detected |
7 |
TSD |
RC |
0h |
Thermal-shutdown detection flag, read to clear the fault
HIGH = Thermal shutdown detected
LOW = Thermal shutdown not detected |
6 |
CMD_ERR |
RC |
0h |
Serial-interface command error, read to clear the fault
HIGH = Command error detected in last serial-interface communication
LOW = No command error detected in last serial-interface communication |
5–0 |
CRC |
R |
0h |
CRC checksum of configuration registers |