SLUU521A August   2011  – November 2021 TPS53353

 

  1.   Trademarks
  2. Description
    1. 1.1 Typical Application
    2. 1.2 Features
  3. Electrical Performance Specifications
  4. Schematic
  5. Test Setup
    1. 4.1 Test Equipment
    2. 4.2 Recommended Test Setup
  6. Configurations
    1. 5.1 Switching Frequency Selection
    2. 5.2 Soft-Start Selection
    3. 5.3 Mode Selection
    4. 5.4 Enable Selection
  7. Test Procedure
    1. 6.1 Line and Load Regulation and Efficiency Measurement Procedure
    2. 6.2 Control Loop Gain and Phase Measurement Procedure
    3. 6.3 Test Point List
    4. 6.4 Equipment Shutdown
  8. Performance Data and Typical Characteristic Curves
    1. 7.1  Efficiency
    2. 7.2  Load Regulation
    3. 7.3  Load Regulation
    4. 7.4  Enable Turn-On/ Turn-Off
    5. 7.5  Output Ripple
    6. 7.6  Switching Node
    7. 7.7  Output Transient With Auto-Skip Mode
    8. 7.8  Output Transient With FCCM Mode
    9. 7.9  Output 0.75-V Prebias Turn-On
    10. 7.10 Output Overcurrent and Short-Circuit Protection
    11. 7.11 Bode Plot
    12. 7.12 Thermal Image
  9. EVM Assembly Drawing and PCB Layout
  10. Bill of Materials
  11. 10Revision History

Test Point List

Table 6-1 Test Point Functions
TEST POINTS NAME DESCRIPTION
TP1 VIN Controller input
TP2 GND Ground
TP3 GND Ground
TP4 EN Enable
TP5 VOUT Output voltage
TP6 LL Switching node
TP7 GND Ground
TP8 PGOOD Power Good
TP9 VREG 5-V LDO output
TP10 CHA Input A for loop injection
TP11 CHB Input B for loop injection
TP12 GND GND