SLUUAQ0C October 2013 – November 2021 TPS53513
Voltage Source: The input voltage source VIN must be a 0-V to 14-V variable DC source capable of supplying 10 ADC. Connect VIN to J1 as shown in Figure 5-2.
Multimeters:
Output Load: The output load must be an electronic constant resistance mode load capable of 15 ADC at 1.2 V.
Oscilloscope: A digital or analog oscilloscope can be used to measure the output ripple. The oscilloscope should be set for the following:
Test points TP7 and TP9 can be used to measure the output ripple voltage by placing the oscilloscope probe tip through TP7 and holding the ground barrel on TP9 as shown in Figure 5-1. Using a leaded ground connection may induce additional noise due to the large ground loop.
Recommended Wire Gauge: