SLUUC54C February 2020 – March 2024 BQ27Z558 , BQ27Z561 , BQ27Z561-R2
This read-word function returns the predicted remaining time to achieve full charge based on AverageCurrent().
I2C Cmd | Name | Access | Proto- col | Type | Min | Max | Unit | Note | ||
---|---|---|---|---|---|---|---|---|---|---|
SE | US | FA | ||||||||
0x18/19 | AverageTimeToFulll() | R | Word | U2 | 0 | 65535 | min |