SLUUC54C February 2020 – March 2024 BQ27Z558 , BQ27Z561 , BQ27Z561-R2
This command enables writing the five advanced charge algorithm charging voltage values in SEALED mode to data flash in the following format: aaAAbbBBccCCddDDeeEE where:
Value | Description | Unit |
---|---|---|
AAaa | Low Temperature Charging Voltage | mV |
BBbb | Standard Temperature Low Charging Voltage | mV |
CCcc | Standard Temperature High Charging Voltage | mV |
DDdd | High Temperature Charging Voltage | mV |
EEee | Recommended Temperature Charging Voltage | mV |