SLUUCA9A September 2020 – April 2021 TPS546B24A
Figure 7-8 and Figure 7-9 show the low-side and high-side MOSFET drain-source voltage (VDS) at 20-A load. The voltage is measured with 1-GHz bandwidth and at the solder mask openings near the U1 IC using a 1-GHz differential probe.