5.5 Overvoltage Cut-off Test
Use the following instructions to perform overvoltage protection test:
- Remove input TVS diodes.
- Set the input supply voltage VIN to 12 V and current limit of 5 A. Apply the supply between input connectors J1 and J3 and enable the power supply.
- Set the load resistance to 24 Ω and connect between VOUT and GND.
- Increase the input supply VIN from 12 V to 18 V and observe the waveforms using an oscilloscope.
Figure 7 shows over voltage response of TPS259804O on TPS25980EVM eFuse Evaluation Board.