SLUUCD3A September 2020 – April 2021 TPS546A24A
The TPS546A24AEVM-1PH includes a 100.0-Ω series resistor in the feedback loop for VOUT. The resistor is accessible at the test points TP16 and TP17 for loop response analysis. These test points should be used during loop response measurements as the perturbation injecting points for the loop . See the description in Table 6-2.
Test Point | Node Name | Description | Comment |
---|---|---|---|
TP16 | CH_A | Input to feedback divider of VOUT | The amplitude of the perturbation at this node should be limited to less than 30 mV |
TP17 | CH_B | Resulting output of VOUT | Bode can be measured by a network analyzer with a CH_B/CH_A configuration |
Measure the loop response with the following procedure: