ON and OFF Control with INP Input

Use the following instructions to verify ON and OFF control of TPS48110-Q1:

  1. Connect the INP (TP6) to ground.
  2. Set the input supply voltage VIN to 48 V and current limit of 10 A.
  3. Enable the power supply.
  4. Now, toggle the INP to HIGH and then LOW to verify the turn-ON and turn-OFF response of PU/PD of TPS48110-Q1.

Figure 5-4 and Figure 5-5 show the turn-ON and turn-OFF responses on the TPS48110Q1EVM Evaluation Board.

Figure 5-4 Turn-ON Response of TPS48110-Q1 for INP -> LOW to HIGH
Figure 5-5 Turn-OFF Response of TPS48110-Q1 for INP -> HIGH to LOW