• Menu
  • Product
  • Email
  • PDF
  • Order now
  • TPS25840-Q1 and TPS25842-Q1 Functional Safety FIT Rate and Failure Mode Distribution

    • SLVAEQ3A February   2020  – July 2020 TPS25840-Q1 , TPS25842-Q1

       

  • CONTENTS
  • SEARCH
  • TPS25840-Q1 and TPS25842-Q1 Functional Safety FIT Rate and Failure Mode Distribution
  1.   Trademarks
  2. 1Overview
  3. 2Functional Safety Failure In Time (FIT) Rates
  4. 3Failure Mode Distribution (FMD)
  5. 4Revision History
  6. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

FUNCTIONAL SAFETY FIT RATE, FMD AND PIN-FMA

TPS25840-Q1 and TPS25842-Q1 Functional Safety FIT Rate and Failure Mode Distribution

Trademarks

All other trademarks are the property of their respective owners.

1 Overview

This document contains information for TPS25840-Q1 and TPS25842-Q1 (VQFN package) to aid in a functional safety system design. Information provided are:

  • Functional Safety Failure In Time (FIT) rates of the semiconductor component estimated by the application of industry reliability standards
  • Component failure modes and their distribution (FMD) based on the primary function of the device

Figure 1-1 shows the device functional block diagram for reference.

GUID-20200615-SS0I-81RZ-MT9P-V2JPBPC4J37H-low.gif Figure 1-1 Functional Block Diagram

TPS25840-Q1 and TPS25842-Q1 were developed using a quality-managed development process, but were not developed in accordance with the IEC 61508 or ISO 26262 standards.

2 Functional Safety Failure In Time (FIT) Rates

This section provides Functional Safety Failure In Time (FIT) rates for TPS25840-Q1 and TPS25842-Q1 based on two different industry-wide used reliability standards:

  • Table 2-1 provides FIT rates based on IEC TR 62380 / ISO 26262 part 11
  • Table 2-2 provides FIT rates based on the Siemens Norm SN 29500-2
Table 2-1 Component Failure Rates per IEC TR 62380 / ISO 26262 Part 11
FIT IEC TR 62380 / ISO 26262-11 (1)FIT (Failures Per 109 Hours)
Total FIT Rate27
Die FIT Rate8
Package FIT Rate19

The failure rate and mission profile information in Table 2-1 comes from the Reliability data handbook IEC TR 62380 / ISO 26262 part 11:

  • Mission Profile: Motor Control from Table 11
  • Power dissipation: 1300 mW
  • Climate type: World-wide Table 8
  • Package factor (lambda 3): Table 17b
  • Substrate Material: FR4
  • EOS FIT rate assumed: 0 FIT
Table 2-2 Component Failure Rates per Siemens Norm SN 29500-2
TableCategoryReference FIT RateReference Virtual TJ
5Digital, Analog, Mixed2555°C

The Reference FIT Rate and Reference Virtual TJ (junction temperature) in Table 2-2 come from the Siemens Norm SN 29500-2 tables 1 through 5. Failure rates under operating conditions are calculated from the reference failure rate and virtual junction temperature using conversion information in SN 29500-2 section 4.

3 Failure Mode Distribution (FMD)

The failure mode distribution estimation for TPS25840-Q1 and TPS25842-Q1 in Table 3-1 comes from the combination of common failure modes listed in standards such as IEC 61508 and ISO 26262, the ratio of sub-circuit function size and complexity and from best engineering judgment.

The failure modes listed in this section reflect random failure events and do not include failures due to misuse or overstress.

Table 3-1 Die Failure Modes and Distribution
Die Failure ModesFailure Mode Distribution (%)
SW no output25%
CSN/OUT not in specification – voltage or timing20%
LS/GD no output5%
LS/GD not in specification – voltage or timing5%
DP_IN, DM_IN, DP_OUT, DM_OUT no output15%
DP_IN, DM_IN, DP_OUT, DM_OUT not in specification – voltage or timing20%
FAULT, BUCK_ST false trip or fails to trip 5%
Short circuit any two pins 5%

 