SLVAEW6 December 2020 TPS2661
As the TPS26610 device provides cut-off protection during miswiring faults, there is no heating and subsequent temperature rise in components during miswiring faults Figure 4-5 provides the temperature rise with TPS26610 during miswiring faults. The temperature of TPS26610 rises ~15°C above ambient temperature during miswiring faults.