SLVSEZ5A July 2020 – December 2020 TPS25814
PRODUCTION DATA
To prevent the possibility of large ground currents into the TPS25814 during sudden disconnects due to inductive effects in a cable, it is recommended that a Schottky diode be placed from VBUS to ground as shown in Figure 8-14.