SLVU435A February 2011 – January 2022 TPS53126
The oscilloscope, analog or digital, must be set for ac-coupled measurement with 20-MHz bandwidth limiting. Use 20-mV/division vertical resolution, 1-µs/division horizontal resolution for output ripple voltage test.
Oscilloscope probes with exposed conductive ground barrels are recommended.