Turn off the input power supply after verifying
that its output voltage is set to the desired supply voltage (less than 17 V)
and the current limit is set to approximately 500 mA. Connect the positive
voltage lead from the input power supply to J3 (VIN) and the ground lead to J4
(GND).
Connect a 0-A to 1-A load (ILoad)
between LDO OUT and GND using J1 and J2.
Disable the output of the LDO by connecting a shorting jumper at JP1 from the “off” pin to the center pin (LDO EN).