SLVUAW9C September 2016 – February 2020 UCD90320
This paged command returns the temperature from an external temperature sensor located in or near an output power module.
NOTE
If no temperature monitor pin is assigned to a rail, the internal temperature sensor is used for that rail. See the MONITOR_CONFIG command (Section 10.6).
Devices other than the UCD90120 and UCD90124: If the user writes this command, the written value will be used as the temperature until another value is written by the user, regardless whether or not a temperature monitor pin is assigned to the rail. When a temperature monitor pin is assigned, once READ_TEMPERATURE_2 is written, the temperature monitor pin will not be used again until the device is reset. Similarly, when no temperature monitor pin is assigned, once READ_TEMPERATURE_2 is written, the internal temperature sensor will not be used again until the device is reset.