The Read Block Paged Command returns the current state of the pages.
Byte Number
(Write) |
Byte Number
(Read) |
Payload Index | Description | |
---|---|---|---|---|
0 | CMD = B9 | |||
1 | 0 | BYTE_COUNT = 1 | ||
2 | 1 | 0 | Rail State(see Table 22) |
RAIL STATE | Value | Description |
---|---|---|
IDLE | 1 | On condition is not met, or rail is shut down due to fault, or rail is waiting for the resequence |
SEQ_ON | 2 | Wait the dependency to be met to assert ENABLE signal |
START_DELAY | 3 | TON_DELAY to assert ENABLE signal |
RAMP_UP | 4 | Enable is asserted and rail is on the way to reach power good threshold. If the power good threshold is set to 0 V, the rail stays at this state even if the monitored voltage is bigger than 0 V. |
REGULATION | 5 | Once the monitoring voltage is over POWER_GOOD when enable signal is asserted, rails stay at this state even if the voltage is below POWER_GOOD late as long as there is no fault action taken. |
SEQ_OFF | 6 | Wait the dependency to be met to de-assert ENABLE signal |
STOP_DELAY | 7 | TOFF_DELAY to de-assert ENABLE signal |
RAMP_DOWN | 8 | Enable signal is de-asserted and rail is ramping down. This state is only available if TOFF_MAX_WARN_LIMIT is not set to unlimited; or If the turn off is triggered by a fault action, rail must not be under fault retry to show RAMP DOWN state. Otherwise, IDLE state is present. |