SLVUAW9C September 2016 – February 2020 UCD90320
This Read Block common command provides fixed information about the device.
Byte Number
(Write) |
Byte Number
(Read) |
Payload
Index |
Description |
---|---|---|---|
0 | CMD = DF | ||
1 | 0 | BYTE_COUNT = 8 | |
2 | 1 | 0 | Maximum Number of Digital Comparators |
3 | 2 | 1 | Maximum Number of General-Purpose Outputs (GPOs) |
4 | 3 | 2 | Maximum Number of General-Purpose Inputs (GPIs) |
5 | 4 | 3 | Maximum Number of Pages |
6 | 5 | 4 | Maximum Number of Fans |
7 | 6 | 5 | Maximum Number of Monitors |
8 | 7 | 6 | Maximum Number of Entries in the Logged Fault Detail (see Section 10.26) |
9 | 8 | 7 | Maximum Number of PWM outputs |
Constant | 90120 | 90120A | 90124 | 90124A | 9090 | 90160 | 90910 | 90240 | 90320 |
---|---|---|---|---|---|---|---|---|---|
Digital Comparators | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 0 | 0 |
GPOs | 12 | 12 | 12 | 12 | 10 | 16 | 10 | 12 | 16 |
GPIs | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 24 | 32 |
Pages | 12 | 12 | 12 | 12 | 10 | 16 | 10 | 24 | 32 |
Fans | 0 | 0 | 4 | 4 | 0 | 0 | 10 | 0 | 0 |
Monitors | 13 | 13 | 13 | 13 | 11 | 16 | 13 | 24 | 32 |
Logged Fault Detail Entries | 16 | 16 | 10 | 12 | 30 | 18 | 12 | 100 | 100 |
PWM outputs | 12 | 12 | 12 | 12 | 10 | 12 | 12 | 24 | 24 |