SLVUAW9C September 2016 – February 2020 UCD90320
The bit definitions for common faults are shown in Table 45.
By examining this single bit (bit 0 of the Non-Paged Faults byte), a host can determine if any page-dependent, GPI, or fan faults have occurred. A value of 0 in this bit indicates that all of the page-dependent, GPI, and fan fault log entries are 0 and need not be read. A value of 1 in this bit indicates that one or more of the page-dependent, GPI, or fan faults have occurred. In that case, the host must examine all of the log entries to determine which ones have log information.
Bit | Description | Can Generate a
LOGGED_FAULT_DETAIL Entry? |
---|---|---|
0 | LOG_NOT_EMPTY | No |
1 | System Watchdog Timeout | Yes |
2 | resequence Error | No |
3 | Watchdog Timeout | Yes |
4 | Reserved | No |
5 | Reserved | No |
6 | Reserved | No |
7 | Reserved | No |