To verify the startup behavior, connect the oscilloscope to the evaluation module:
- Channel 1 - Input Voltage (Test Point Label VIN)
- Channel 2 - Output Voltage (Test Point Label VOUT)
- Channel 3 - DGATE Voltage (Test Point Label DGATE)
- Channel 4 - HGATE Voltage (Test Point Label HGATE)
Set the load to 200 mA, trigger to Channel 1 rising and turn ON the power supply. Startup behavior of LM74810EVM-CD is captured in
Figure 5-2.
Figure 5-2 Power up: DGATE and HGATE Figure 5-3 Power Up: Charge Pump and Inrush Current Additional startup information is captured in Figure 5-3. Channel 3 captures the charge pump voltage on VCAP pin during startup. Charge pump turns on when POR threshold on VIN is reached and builds up to 13.5 V above VIN.