SLVUCE1A march 2023 – august 2023 TPS56837
To change the output voltage of the EVMs, change the value of resistor R6 (RFB_TOP) and resistor R7 (RFB_BOT). Changing the value of R6 and R7 can change the output voltage above 0.6 V. The value of R6 and R7 for a specific output voltage can be calculated using Equation 1.
Table 3-1 lists the R6 and R7 values for some common output voltages.
Switching Frequency (kHz) | Output Voltage(1) (V) | R6(2) (kΩ) | R7 (kΩ) | L1 (µH) | COUT(3) (µF) | C10 (4)(pF) |
---|---|---|---|---|---|---|
TYP | ||||||
500 | 1.05 | 7.5 | 10 | 1 | 68 | |
1.8 | 20 | 10 | 1.5 | 68 | ||
3.3 | 45.3 | 10 | 2.2 | 62 | 150 | |
5 | 73.2 | 10 | 3.3 | 35 | 150 | |
9 | 140 | 10 | 4.7 | 22 | 100 | |
12 | 383 | 20 | 5.6 | 17 | 30 | |
800 | 1.05 | 7.5 | 10 | 0.68 | 68 | |
1.8 | 20 | 10 | 1 | 68 | ||
3.3 | 45.3 | 10 | 1.5 | 62 | 150 | |
5 | 73.2 | 10 | 2.2 | 35 | 150 | |
9 | 140 | 10 | 3.3 | 22 | 100 | |
12 | 383 | 20 | 3.3 | 17 | 30 | |
1200 | 1.05 | 7.5 | 10 | 0.47 | 68 | |
1.8 | 20 | 10 | 0.68 | 68 | ||
3.3 | 45.3 | 10 | 1 | 62 | 150 | |
5 | 73.2 | 10 | 1.5 | 35 | 150 | |
9 | 140 | 10 | 2.2 | 22 | 100 | |
12 | 383 | 20 | 2.2 | 17 | 30 |