SNLA364C March 2021 – June 2022 DP83TD510E
The DP83TD510E is IEEE 802.3cg 10Base-T1L compliant. The device supports all the required test modes within the standard for assessing PHY compliance.
When testing the PMA compliance of the DP83TD510E, it is necessary to configure the PHY into the appropriate test mode. The IEEE 802.3cg specifies three test modes to measure the transmitter’s waveform, distortion, jitter, and droop. The IEEE 802.3cg standard specifies limits for both 1.0 Vpp and 2.4 Vpp output operating modes.
Test | Limit | ||
---|---|---|---|
1.0 Vpp mode | 2.4 Vpp mode | ||
Output Voltage | Maximum | 1.05 mV | 2.520 mV |
Minimum | 0.850 mV | 2.040 mV | |
Droop | Positive | 10% | 10% |
Negative | 10% | 10% | |
Jitter | 10 ns | ||
PSD | Mask | Template | Template |
Power Level | -0.2 – 2.2 dBm | 7.4 – 9.8 dBm |
The default output operating mode will be 1.0 Vpp without a link partner detected. Select the output operating mode of the DP83TD510E by running the script below for 2.4 Vpp in the 1-V and 2.4-V p2p mode session for the test mode 1, 2, and 3.
//Set Output operating mode for 2.4 Vpp for test mode 1,2,and 3
begin
000D 0001
000E 08F6
000D 4001
000E 1000 //force 2.4V
000D 001F
000E 0016
000D 401F
000E 0104 //enable digital loopback to force link up to have three level signal
end
begin
000d 0001
000e 08f8
000d 4001
000e 2000 //Set test mode 1 in MMD 01
001f 4000 //soft reset
end
begin
000d 0001
000e 08f8
000d 4001
000e 4000 //Set test mode 2 in MMD 01
001f 4000 //soft reset
end
begin
000d 0001
000e 08f8
000d 4001
000e 6000 //Set test mode 1 in MMD 01
001f 4000 //soft reset
end
begin
//001f 8000 //hard reset
000d 0007
000e 0200
000d 4007
000e 0000 //disable autoneg MMD 07
000d 0001
000e 0834
000d 4001
000e 0000 //Force Slave Mode MMD 01
000d 0001
000e 08f6
000d 4001
000e 0000 //Force 1V swing MMD 01
001f 4000 //soft reset
end
begin
//001f 8000 //hard reset
000d 0007
000e 0200
000d 4007
000e 0000 //disable autoneg MMD 07
000d 0001
000e 0834
000d 4001
000e 0000 //Force Slave Mode MMD 01
000d 0001
000e 08f6
000d 4001
000e 1000 //Force 2.4V swing MMD 01
001f 4000 //soft reset
end