SNOA961A February 2017 – February 2023 LDC2112 , LDC2114 , LDC3114 , LDC3114-Q1
The sensor Quality Factor Q measures the ratio of the sensor inductance to the sensor’s AC resistance. In general, a higher value is desirable, as the sensor requires less energy to maintain oscillation. Use Equation 3 to calculate the sensor Q.
The RS is the sensor’s series AC resistance at the frequency of operation. The sensor Q can be increased by either increasing the sensor inductance, decreasing the sensor RS, or decreasing capacitance.