Button Actuation Time

The minimum button actuation time is the hysteresis value divided by the baseline increment. Figure 5-4 shows the output codes and OUTx assertion for the same stimuli with different baseline increment settings. Larger values of baseline increment can effectively “turn-off” a button before the actual stimuli has been removed.

GUID-F44D0AF1-D9F5-4907-81BE-D2D6B1815F22-low.png Figure 5-4 Effect of Baseline Increment on Minimum Actuation time