SNOU189 May 2022 TLV3811
C7 and C8 are installed with 0.1-uF capacitors. If a 100-Ω differential probe is unavailable to measure the LVDS output, these capacitors allow for the AC portion of the signal to be seen on a 50-Ω terminated scope. Keep in mind that any duty cycle other than 50% will result in a DC portion of the signal that is not halfway between VOH and VOL. As mentioned earlier, this is because of the charging and discharging of the capacitors. A higher duty cycle will result in a higher DC output voltage because the capacitors are charging more than they are discharging.
If equipment is available to measure the LVDS output with a respect to the 100-Ω resistor or with a differential probe, then C7 and C8 can be replaced with 0-Ω resistors to keep the DC integrity of the output signal.