SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
The UART device operates in three modes:
To be used as a UART, the operating mode must be programmed appropriately in the UARTi.UART_MDR1[2:0] MODE_SELECT bit field to select UART, IrDA, or CIR mode.
The UART uses a wired interface for serial communication with a remote device.
The UART is functionally compatible with the TL16C750 UART and earlier designs such as the TL16C550.
Figure 24-39 shows the UART frame data format.