SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
To select a mode, set the UARTi.UART_MDR1[2:0] MODE_SELECT bit field (see Table 24-106).
Value | Mode |
---|---|
0x0: | UART 16x mode |
0x1: | SIR mode (UART3 only) |
0x2: | UART 16x auto-baud |
0x3: | UART 13x mode |
0x4: | MIR mode (UART3 only) |
0x5: | FIR mode (UART3 only) |
0x6: | CIR mode (UART3 only) |
MODE_SELECT is effective when the module is in operational mode (see Section 24.3.4.7.1, Register Access Modes).