SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
The GPMC offers maximum flexibility to support various access protocols. Most of the timing parameters of the protocol access used by the GPMC to communicate with attached memories or devices are programmable on a chip-select basis. Assertion and deassertion times of control signals are defined to match the attached memory or device timing specifications and to get maximum performance during accesses. For more information about GPMC_CLK and GPMC_FCLK see Section 15.4.4.9.6, GPMC_CLK.
In the following sections, the start access time refers to the time at which the access begins.