SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
Step | Register/ Bit Field / Programming Model | Value |
---|---|---|
IF : Is FIFO full ? | MAILBOX_FIFOSTATUS_m[0] FIFOFULLMB | = 0x1 |
Wait until at least one message slot is available | MAILBOX_FIFOSTATUS_m[0] FIFOFULLMB | = 0x0 |
ELSE | ||
Write message | MAILBOX_MESSAGE_m[31:0] MESSAGEVALUEMBM | 0x---- |
ENDIF |