SPRUIE9D May 2017 – May 2024 DRA74P , DRA75P , DRA76P , DRA77P
The procedure in Table 17-27 provides the configuration settings and LUT refill.
Step | Register/Bit Field/Programming Model | Value |
---|---|---|
PAT configuration refill Engine 0 | DMM_PAT_CONFIG[0] MODE0 | xxx |
PAT configuration refill Engine 1 | DMM_PAT_CONFIG[1] MODE1 | xxx |
Set DMM PAT view register value for each initiator. | DMM_PAT_VIEW0 Vx DMM_PAT_VIEW1 Vx | xxx |
Set DMM PAT write enable for the initiators. | DMM_PAT_VIEW0 Wx DMM_PAT_VIEW1 Wx | xxx |
Choosing container type and access method | DMM_PAT_VIEW_MAP_i | xxx |
Define the base address of all view mappings. | DMM_PAT_VIEW_MAP_BASE[31] BASE_ADDR | xxx |
Set area definition for DMM physical address translator. | DMM_PAT_AREA_i | xxx |
Set the physical address of the current table refill entry data or entry data when in manual mode. | DMM_PAT_DATA_i[31:4] ADDR | xxx |
Define the direction of this PAT table refill (S Y X), different from 0x011. | DMM_PAT_CTRL_i[6:4] DIRECTION | xxx |
Start a PAT table refill. | DMM_PAT_CTRL_i[0] START | 0x1 |