SPRUIE9D May 2017 – May 2024 DRA74P , DRA75P , DRA76P , DRA77P
GLBCE has minimum input restriction of 480x240. The input must be at least this size.
After reset, GLBCE goes into initialization state of 554 clock cycles. While in this state, filtering flag is raised, and not input image may come into GLBCE module.
GLBCE LUTs must not be changed during the active frames. They can only be updated in vertical blanking. GLBCE_LUT_FI may be changed frame by frame depending on the GLBCE tuning method. Other LUTs (GLBCE_REV_PERCEPT_LUT_xx, GLBCE_FWD_PERCEPT_LUT_xx, and GLBCE_WDR_GAMMA_LUT_xx) are not expected to be updated dynamically except in very limited case.