SPRZ423K October 2014 – May 2024 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076
SDFM: Comparator Filter Module may Generate Spurious Over-Value and Under-Value Conditions
B, C
When interrupts are enabled in the SDFM comparator module, it may trigger spurious over-value (SDIFLG.IEHx, x = 1 to 4) or under-value (SDIFLG.IELx, x = 1 to 4) conditions. These are depicted as IELx and IEHx interrupt outputs in the “Block Diagram of One Filter Module” figure in the TMS320F2807x Real-Time Microcontrollers Technical Reference Manual.
These erroneous interrupts can be eliminated by implementing the following workaround: