SPRZ458F May 2019 – February 2024 TMS320F28384D , TMS320F28384D-Q1 , TMS320F28384S , TMS320F28384S-Q1 , TMS320F28386D , TMS320F28386D-Q1 , TMS320F28386S , TMS320F28386S-Q1 , TMS320F28388D , TMS320F28388S
HWBIST: No Cross-Triggering From One CPU While One of the C28x Cores is Going Through HWBIST Check
0, A
While HWBIST check is ongoing on one of the C28x cores, any cross-trigger events from other CPUs (second C28x core or CM) can cause the HWBIST check to fail. This is due to the fact that cross-trigger input is missing an input isolation during HWBIST.
No cross-triggering should be done while HWBIST is active.