SWRA478D February   2015  – January 2019 CC1310 , CC1312PSIP , CC1312R , CC1314R10 , CC1352P , CC1352P7 , CC1352R , CC2640 , CC2640R2F , CC2640R2F-Q1 , CC2642R , CC2642R-Q1 , CC2650 , CC2650MODA , CC2652P , CC2652R , CC2652R7 , CC2652RB , CC2652RSIP

 

  1.   Trademarks
  2. 1Introduction
    1. 1.1 Acronyms
  3. 2Standby
  4. 3Understanding Bluetooth Low Energy Power Metrics
  5. 4SimpleLink Bluetooth Low Energy Wireless MCUs
  6. 5Power Measurement Setup – Preparing the DUT
    1. 5.1 Requirements
    2. 5.2 Embedded Software
    3. 5.3 Hardware
      1. 5.3.1 CC26x2R LaunchPad
    4. 5.4 BTool (Optional)
  7. 6Measuring Power Consumption With a DC Power Analyzer
    1. 6.1 Test Setup
      1. 6.1.1 Analysis Software Setup
    2. 6.2 Measurement Using Scope
    3. 6.3 Analysis
      1. 6.3.1 Advertising Event
      2. 6.3.2 Connection Event
      3. 6.3.3 Power Consumption Calculator
  8. 7EnergyTrace
    1. 7.1 Modifying the rfPacketTX Example
  9. 8References
  10. 9Revision History

Test Setup

Make sure that the system is set up properly and review the steps described in Section 5. For reference, the full overview is illustrated in Figure 6-2. VDD is connected to the 3V3 pin on the LaunchPad.

When the DUT is correctly connected, the power supply is enabled by pressing the “On” button within the Agilent 14585A Control and Analysis Software. The power consumption measurements can be done by two separate functions: Scope or Data Logger. The Data Logger provides an average power consumption measurement over longer time, for example, minutes and hours, although the resolution is not as good as using Scope. This document focuses on doing measurements by using the Scope feature.

GUID-689C126A-8DCF-4A02-BC41-4B97BD44152E-low.gifFigure 6-2 DUT Test Setup

The Agilent N6705B powers the DUT as well as performs the current measurement.