SFFS009 December   2021 LM60-Q1

 

  1. 1Overview
  2. 2Functional Safety Failure In Time (FIT) Rates
    1. 2.1 SOT-23-3 Package
  3. 3Failure Mode Distribution (FMD)

Overview

This document contains information for LM60-Q1 ( SOT-23-3 package) to aid in a functional safety system design. Information provided are:

  • Functional Safety Failure In Time (FIT) rates of the semiconductor component estimated by the application of industry reliability standards
  • Component failure modes and their distribution (FMD) based on the primary function of the device

Figure 1-1 shows the device functional block diagram for reference.

GUID-301558B4-EFB4-44A0-83AE-1AD2EA8BBF53-low.gifFigure 1-1 Functional Block Diagram

LM60-Q1 was developed using a quality-managed development process, but was not developed in accordance with the IEC 61508 or ISO 26262 standards.