10 Revision History
Changes from Revision C (May 2023) to Revision D (July 2024)
- Updated GUI software image to latest version.Go
- Added DMD Communication Error to
the list of descriptions of status
indicatorsGo
- Added DMD Faults status sectionGo
- Updated Video Mode Panel - Source Settings Tab
figureGo
- Updated Video Mode Panel - Display Settings Tab
figureGo
- Added Note that names in Figure 6-11 and Figure 6-12 do not appear in the GUI.Go
- Updated Pattern Settings Panel image and added LED Controls
invert function description.Go
- Added Peripheral Panel to accommodate new Debug
section.Go
- Added Peripherals Tab figureGo
- Added Debug Tab sectionGo
- Changed the pinout table in DLPC900
UART
Go
Changes from Revision B (July 2022) to Revision C (May 2023)
- Fixed J23 pin 11 to correctly reflect 3.3V
connectionGo
- Added J26 to the table of pin connectionsGo
- Changed the pulse length of trigger output 2 as
19.4μsGo
- Changed that trigger input 1 advances to the next pattern waiting
for a trigger inputGo
- Added information regarding supported GUI and firmware versions for
the DLP5500 DMDGo
- Added descriptions of items in DLPC900REF-SWGo
- Added DLPA200 fault to the list of
descriptions of status indicatorsGo
- Added information about the DLPA200 fault
conditionsGo
- Added information that the Get command only reads values from the
primary controllerGo
- Added note that the EVM is connected only on Pixel Clock
1Go
- Added link to table in DLPC900 Programmer's Guide of minimum exposure timesGo
- Added note requiring an Update LUT command to resume
operation after stopping DMD Idle Mode
Go
- Added a note to the Caution statement regarding supported GUI and
firmware versions for the DLP5500 DMDGo
- Added information about the number of patterns the EVM can hold in
flash memoryGo
- Added information to the caution note about the recommended firmware
versionGo
- Added new section to describe how to reprogram firmware to support a different
DMDGo
- Updated Figure 6-26
changing Cypress to InfineonGo
- Added section describing how to program an EDIDGo
- Added pin J18 table and
description Go
- Created new section for pin J26Go
- Changed minimum current from 0A to 5AGo
- Added information about J18 matching connectorGo
Changes from Revision A (April 2022) to Revision B (July
2022)
- Changed all instances of legacy terminology to Primary and
Secondary throughoutGo
- Added note: heartbeat is present even if no DMD is
present.Go
- Changed J11 HOLDBoot jumper description to BOOTHold
jumper.Go
- Added Controller Board and DMD Board Assembly
instructions.Go
- Updated to Secondary terminology
for Secondary Present and Ready Status
item.Go