SBAS790C October 2018 – June 2019 ADS125H02
PRODUCTION DATA.
STATUS2 is shown in Figure 96 and described in Table 44.
Return to Register Map Summary.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
0 | 0 | LOCK2 | CRC2 | REV_ID2[3:0] | |||
R/W-0h | R/W-0h | R-0h | R/W-0h | R/W-xh |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7:6 | 0 | R/W | 0h |
Reserved Always write 0. |
5 | LOCK2 | R | 0h |
Register Write Lock2 Status Indicates the register write lock status of registers 10h to 12h. See the LOCK Command section for details. 0: Registers 10h to 12h are not locked (default) 1: Registers 10h to 12h are locked See the STATUS2 register for the register write lock status of registers 00h to 0fh. |
4 | CRC2 | R/W | 0h |
CRC2 Error Indicates if a CRC error occurred during commands with CS2. The CRC error is latched until cleared by the user. Write 0 to clear the error. 0: No CRC error during commands with CS2 1: CRC error occurred during commands with CS2 |
3:0 | REV_ID2[3:0] | R | x |
Revision ID2 Revision ID 2 field. The revision ID1 and ID2 can change without notification. |