SBAU227A March 2014 – June 2021 TPS56520 , TPS56720 , TPS56920 , TPS56C20
The TPS56C20EVM-614 provides input/output connectors and test points as shown in Table 4-1. The design requires a power supply capable of supplying 4 A to connect to J1 through a pair of 20-AWG wires. The design requires the load to connect to J3 through a pair of 20-AWG wires. The maximum load current capability is 12 A. Wire lengths must be minimized to reduce losses in the wires. Test point TP3 provides a place to monitor the VIN input voltages with TP4 (which provides a convenient ground reference). The design uses TP6 to monitor the output voltage with TP7 as the ground reference.
Reference Designator | Function |
---|---|
J1 | PVIN input voltage connector (See Table 1-1 for PVIN range) |
J2 | VIN input voltage connector. Not normally used |
J3 | VOUT, 1.1V at 12A maximum |
JP1 | PVIN to VIN jumper. Normally closed |
JP2 | I2C interface pull up jumper for SDA |
JP3 | I2C interface pull up jumper for SCL |
JP4 | I2C interface grounding jumper for A1 |
JP5 | I2C interface grounding jumper for A0 |
JP6 | Enable Jumper. Close to disable, open to enable |
TP1 | GND test point for VIN connector |
TP2 | VIN test point |
TP3 | PVIN test point |
TP4 | GND test point for PVIN connector |
TP5 | SW test point |
TP6 | Output voltage test point at VOUT connector |
TP7 | GND test point at VOUT connector |
TP9 | Analog GND test point |
TP10 | Test point in voltage divider network. Used for loop response measurements |