SBOS854F March   2018  – June 2024 TMP1075

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics:TMP1075
    6. 6.6  Electrical Characteristics: TMP1075N
    7. 6.7  Timing Requirements:TMP1075
    8. 6.8  Timing Requirements: TMP1075N
    9. 6.9  Switching Characteristics
    10. 6.10 Timing Diagrams
    11. 6.11 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Digital Temperature Output
      2. 7.3.2 I2C and SMBus Serial Interface
        1. 7.3.2.1  Bus Overview
        2. 7.3.2.2  Serial Bus Address
        3. 7.3.2.3  Pointer Register
          1. 7.3.2.3.1 Pointer Register Byte [reset = 00h]
        4. 7.3.2.4  Writing and Reading to the TMP1075
        5. 7.3.2.5  Operation Mode
          1. 7.3.2.5.1 Receiver Mode
          2. 7.3.2.5.2 Transmitter Mode
        6. 7.3.2.6  SMBus Alert Function
        7. 7.3.2.7  General Call- Reset Function
        8. 7.3.2.8  High-Speed Mode (HS)
        9. 7.3.2.9  Coexists in I3C Mixed Fast Mode
        10. 7.3.2.10 Time-Out Function
      3. 7.3.3 Timing Diagrams
      4. 7.3.4 Two-Wire Timing Diagrams
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode (SD)
      2. 7.4.2 One-Shot Mode (OS)
      3. 7.4.3 Continuous Conversion Mode (CC)
      4. 7.4.4 Thermostat Mode (TM)
        1. 7.4.4.1 Comparator Mode (TM = 0)
        2. 7.4.4.2 Interrupt Mode (TM = 1)
        3. 7.4.4.3 Polarity Mode (POL)
    5. 7.5 Register Map
      1. 7.5.1 Register Descriptions
        1. 7.5.1.1 Temperature Register (address = 00h) [default reset = 0000h]
        2. 7.5.1.2 Configuration Register (address = 01h) [default reset = 00FFh (60A0h TMP1075N)]
        3. 7.5.1.3 Low Limit Register (address = 02h) [default reset = 4B00h]
        4. 7.5.1.4 High Limit Register (address = 03h) [default reset = 5000h]
        5. 7.5.1.5 Device ID Register (address = 0Fh) [default reset = 7500]
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Migrating From the xx75 Device Family
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Digital Temperature Output

The digital output from each temperature measurement conversion is stored in the read-only temperature register. Which is a 12-bit, read-only register that stores the output of the most recent conversion. Two bytes must be read to obtain data. However, only the first 12 MSBs are used to indicate temperature while the remaining 4 LSB are set to zero. Table 7-1 lists the data format for the temperature. Negative numbers are represented in binary two's-complement format. After power-up or reset, the temperature register reads 0°C until the first conversion is complete.

Table 7-1 Temperature Data Format
TEMPERATURE
(°C)
DIGITAL OUTPUT
BINARYHEX
127.93750111 1111 1111 00007FF0
1000110 0100 0000 00006400
800101 0000 0000 00005000
750100 1011 0000 00004B00
500011 0010 0000 00003200
250001 1001 0000 00001900
0.250000 0000 0100 00000040
0.06250000 0000 0001 00000010
00000 0000 0000 00000000
–0.06251111 1111 1111 0000FFF0
–0.251111 1111 1100 0000FFC0
–251110 0111 0000 0000E700
–501100 1110 0000 0000CE00
–1281000 000 0000 00008000