SBOSAA3A July 2024 – November 2024 TRF1108
PRODUCTION DATA
Figure 6-2 shows that the TRF1108 can be dc-coupled with the help of an application circuit. Operate on VDD = +1.68V and VSS = –3.32V supplies to set the output dc-bias level to 0V. Externally set the input common-mode voltage to –1.98V to bias the device. A resistive level shifter network, along with external bias voltages, translates output common-mode of the DAC to input common-mode of the amplifier.